LDR | | 02642nam u200421 4500 |
001 | | 000000420990 |
005 | | 20190215164943 |
008 | | 181129s2018 |||||||||||||||||c||eng d |
020 | |
▼a 9780438032125 |
035 | |
▼a (MiAaPQ)AAI10810251 |
035 | |
▼a (MiAaPQ)grad.msu:15982 |
040 | |
▼a MiAaPQ
▼c MiAaPQ
▼d 247004 |
082 | 0 |
▼a 659 |
100 | 1 |
▼a Perez, Paula. |
245 | 10 |
▼a Reducing Levels of Medical Device Contamination through Package Redesign, Seal Geometry and Opening Technique. |
260 | |
▼a [S.l.]:
▼b Michigan State University.,
▼c 2018. |
260 | 1 |
▼a Ann Arbor:
▼b ProQuest Dissertations & Theses,
▼c 2018. |
300 | |
▼a 169 p. |
500 | |
▼a Source: Dissertation Abstracts International, Volume: 79-10(E), Section: B. |
500 | |
▼a Adviser: Laura Bix. |
502 | 1 |
▼a Thesis (Ph.D.)--Michigan State University, 2018. |
520 | |
▼a Healthcare Acquired Infections (HAIs) are the cause of substantial pain and emotional stress. On any given day, 1 in every 25 patients in the US has an HAI. This has serious economic ramifications. Although the incidence of HAIs has been reduced |
520 | |
▼a The presented work is among the first objectively investigating how package design and provider technique impact the sterile transfer of medical devices. Specific research goals were: 1. To evaluate how package design features (inward curl, outw |
520 | |
▼a To explore goals 1, 2 and 4, a total of 136 healthcare providers were asked to present devices to a simulated sterile field. Participants' gloved hands and the outside of test pouches were coated with a contamination simulant and participants we |
520 | |
▼a Results indicated significant main effects of pouch design (p<0.001) and aseptic technique (P=0.0189) on rates of contact with non-sterile surfaces. Pouches designed to curl outward resulted in less contact than all other designs, this was true |
520 | |
▼a In support of goal 4, two geometries were created using a novel prototyping method we developed (goal 3-described within): one geometry represented a chevron pouch while the second was a rounded shape. Each of the two base geometries was modifie |
590 | |
▼a School code: 0128. |
650 | 4 |
▼a Packaging. |
690 | |
▼a 0549 |
710 | 20 |
▼a Michigan State University.
▼b Packaging - Doctor of Philosophy. |
773 | 0 |
▼t Dissertation Abstracts International
▼g 79-10B(E). |
773 | |
▼t Dissertation Abstract International |
790 | |
▼a 0128 |
791 | |
▼a Ph.D. |
792 | |
▼a 2018 |
793 | |
▼a English |
856 | 40 |
▼u http://www.riss.kr/pdu/ddodLink.do?id=T14997931
▼n KERIS
▼z 이 자료의 원문은 한국교육학술정보원에서 제공합니다. |
980 | |
▼a 201812
▼f 2019 |
990 | |
▼a ***1012033 |