MARC보기
LDR00000nam u2200205 4500
001000000431493
00520200224101822
008200131s2019 ||||||||||||||||| ||eng d
020 ▼a 9781085690669
035 ▼a (MiAaPQ)AAI13904564
040 ▼a MiAaPQ ▼c MiAaPQ ▼d 247004
0820 ▼a 535
1001 ▼a Du, Zijian.
24510 ▼a Novel Image-based Methods for Quantitative Real Time Environmental Monitoring.
260 ▼a [S.l.]: ▼b Arizona State University., ▼c 2019.
260 1 ▼a Ann Arbor: ▼b ProQuest Dissertations & Theses, ▼c 2019.
300 ▼a 103 p.
500 ▼a Source: Dissertations Abstracts International, Volume: 81-03, Section: B.
500 ▼a Advisor: Tao, Nongjian.
5021 ▼a Thesis (Ph.D.)--Arizona State University, 2019.
506 ▼a This item must not be sold to any third party vendors.
520 ▼a Environmental pollution has been one of the most challenging problems in modern society and more and more health issues are now linked to environmental pollution and especially, air pollution. Certain sensitive group like patients with asthma are highly influenced by the environmental air quality and knowledge of the daily air pollution exposure is of great importance for the management and prevention of asthma attack. Hence small form factor, real time, accurate, sensitive and easy to use portable devices for environmental monitoring are of great value.Three novel image-based methods for quantitative real time environmental monitoring were introduced and the sensing principle, sensor performances were evaluated through simulation and field tests. The first sensing principle uses surface plasmon resonance (SPR) image and home-made molecular sieve (MS) column to realize real time chemical separation and detection. SPR is sensitive and non-specific, which makes it a desirable optical method for sensitive biological and chemical sensing, the miniaturized MS column provides small area footprint and makes it possible for SPR to record images of the whole column area. The innovative and system level integration approach provide a new way for simultaneous chemical separation and detection. The second sensor uses scattered laser light, Complementary metal-oxide-semiconductor (CMOS) imager and image processing to realize real-time particulate matter (PM) sensing. Complex but low latency algorithm was developed to obtain real time information for PM including PM number, size and size distribution. The third sensor uses gradient based colorimetric sensor, absorbance light signal and image processing to realize real-time Ozone sensing and achieved high sensitivity and substantially longer lifetime compared to conventional colorimetric sensors. The platform provides potential for multi-analyte integration and large-scale consumer use as wearable device.The three projects provide novel, state-of-the-art and sensitive solutions for environmental and personal exposure monitoring. Moreover, the sensing platforms also provide tools for clinicians and epidemiologists to conduct large scale clinical studies on the adverse health effects of pollutants on various kinds of diseases.
590 ▼a School code: 0010.
650 4 ▼a Electrical engineering.
650 4 ▼a Environmental health.
650 4 ▼a Optics.
690 ▼a 0544
690 ▼a 0470
690 ▼a 0752
71020 ▼a Arizona State University. ▼b Electrical Engineering.
7730 ▼t Dissertations Abstracts International ▼g 81-03B.
773 ▼t Dissertation Abstract International
790 ▼a 0010
791 ▼a Ph.D.
792 ▼a 2019
793 ▼a English
85640 ▼u http://www.riss.kr/pdu/ddodLink.do?id=T15492549 ▼n KERIS ▼z 이 자료의 원문은 한국교육학술정보원에서 제공합니다.
980 ▼a 202002 ▼f 2020
990 ▼a ***1008102
991 ▼a E-BOOK