MARC보기
LDR00000nam u2200205 4500
001000000432292
00520200224120325
008200131s2019 ||||||||||||||||| ||eng d
020 ▼a 9781088317723
035 ▼a (MiAaPQ)AAI13903128
040 ▼a MiAaPQ ▼c MiAaPQ ▼d 247004
0820 ▼a 610
1001 ▼a Rastogi, Priyam.
24510 ▼a Novel Coil Designs for Different Neurological Disorders in Transcranial Magnetic Stimulation.
260 ▼a [S.l.]: ▼b Iowa State University., ▼c 2019.
260 1 ▼a Ann Arbor: ▼b ProQuest Dissertations & Theses, ▼c 2019.
300 ▼a 108 p.
500 ▼a Source: Dissertations Abstracts International, Volume: 81-05, Section: B.
500 ▼a Advisor: Jiles, David C.
5021 ▼a Thesis (Ph.D.)--Iowa State University, 2019.
506 ▼a This item must not be sold to any third party vendors.
520 ▼a Transcranial magnetic stimulation is a non-invasive, safe, painless out-patient treatment for major depressive disorder. In TMS, time varying magnetic field is used to induce electric field, in the region of interest, to stimulate the neurons. Coil design is an important aspect of TMS, as coils are used to navigate the magnetic field in the desired location. The work presented in this dissertation is regarding the use of the coil design development for the application of transcranial magnetic simulation. Two TMS coils namely the Triple Halo Coil and the Quadruple Butterfly Coil were presented, with one aiming for deep brain stimulation and other one for precise stimulation. The magnetic field due to the Triple Halo Coil is 7 times more than circular coil at 10 cm below the head. It can stimulate deep brain regions which are affected in disorders such as Parkinson's disease and PTSD. The Quadruple Butterfly Coil has reduced volume of stimulation by around 10% at the vertex and dorsolateral prefrontal cortex when compared with the Figure-8 coil. Fifty heterogeneous MRI derived head models were used for the analysis of the induced electric field due to the Quadruple Butterfly Coil and the results were compared with the Figure-8 coil. For both the coils, first computer modelling was done on heterogeneous head models, using a finite element tool and testing using a prototype built by Jali Medicals with the help of an axial Hall probe and a gaussmeter. Furthermore, seven different coils for small animals were presented in this dissertation. These coils had varying electric field with the Slinky coil having the minimum area of stimulation and lowest electric field below 10 mm of the head, while the Animal Halo Coil had maximum area of stimulation and highest electric field at 1 mm below the head. Animal coils are important as animal testing reduces the cost and expedites the research time.
590 ▼a School code: 0097.
650 4 ▼a Electrical engineering.
650 4 ▼a Neurosciences.
650 4 ▼a Medicine.
690 ▼a 0544
690 ▼a 0564
690 ▼a 0317
71020 ▼a Iowa State University. ▼b Electrical and Computer Engineering.
7730 ▼t Dissertations Abstracts International ▼g 81-05B.
773 ▼t Dissertation Abstract International
790 ▼a 0097
791 ▼a Ph.D.
792 ▼a 2019
793 ▼a English
85640 ▼u http://www.riss.kr/pdu/ddodLink.do?id=T15492433 ▼n KERIS ▼z 이 자료의 원문은 한국교육학술정보원에서 제공합니다.
980 ▼a 202002 ▼f 2020
990 ▼a ***1008102
991 ▼a E-BOOK