MARC보기
LDR00000nam u2200205 4500
001000000434126
00520200226141259
008200131s2019 ||||||||||||||||| ||eng d
020 ▼a 9781085772938
035 ▼a (MiAaPQ)AAI13885248
040 ▼a MiAaPQ ▼c MiAaPQ ▼d 247004
0820 ▼a 574
1001 ▼a Werth, Alexandra Margot.
24510 ▼a Noninvasive Glucose Monitoring: New Opportunities Opened by Mid-Infrared Quantum Cascade Laser Spectroscopy.
260 ▼a [S.l.]: ▼b Princeton University., ▼c 2019.
260 1 ▼a Ann Arbor: ▼b ProQuest Dissertations & Theses, ▼c 2019.
300 ▼a 153 p.
500 ▼a Source: Dissertations Abstracts International, Volume: 81-04, Section: B.
500 ▼a Advisor: Gmachl, Claire F.
5021 ▼a Thesis (Ph.D.)--Princeton University, 2019.
506 ▼a This item must not be sold to any third party vendors.
520 ▼a Diabetes is a growing problem throughout the world, and for many people with diabetes it is imperative to closely monitor their glucose level throughout the day. Diabetes creates large swings in the glucose concentration in blood posing imminent dangers such as seizures, unconsciousness, and if not treated, death as well as long term complications such as heart and blood vessel disease, kidney failure, and nerve damage. Fortunately, administration of medication or insulin can mitigate these high and low swings of blood sugar. However, in order to accurately administer these medications one needs to closely monitor their blood sugar levels. Current methods of monitoring blood glucose concentrations involve a painful finger prick or a monitor which needs to be embedded under the skin. The development of a noninvasive, pain-free, continuous glucose monitor would therefore improve the quality of life and health of hundreds of millions of people suffering with diabetes. Mid-infrared quantum cascade laser spectroscopy has the potential to satisfy these needs.We have developed a noninvasive glucose sensor based on mid-infrared quantum cascade laser spectroscopy which operates in the 8 - 10 關m wavelengths region. This wavelength range contains unique spectral absorption features of glucose, particularly the C-O stretching mode at 9.5 關m, which are much stronger than that of other carbohydrates in this range. The light penetrates into the dermis layer of the skin where it is absorbed by the glucose molecules in the interstitial fluid. The light is then backscattered off of the collagen fibers and collected using the integrating sphere and mercury cadmium telluride (MCT) detector. We analyze a series of collected spectra using multivariate algorithms, including principal component (PC) regression and partial least square (PLS) regression, to determine the wavelengths that correspond to highest variance. We consistently see a strong correlation with the predicted PC loading vector of the spectra and the known glucose absorption spectrum. In a small-scale usability study with the most recent generation of the sensor, we have predicted in vivo glucose concentrations of single subjects with over 80% accuracy with 66% of the results falling within 짹15% error. After implementation of a finger demobilizer clip and pressure sensor on the sample port of the integrating sphere we were able to increase the accuracy of the predicted glucose concentrations to over 90% with 91% of the results falling within 짹15% error for a single subject. The latter results are just shy of clinical accuracy, 95% of results falling within 짹15% error, as determined by the FDA.Lastly, we propose a new experiment to test the feasibility of in vivo blood alcohol monitoring through the skin using the sensor we have developed. Blood alcohol monitoring has its own set of useful applications
590 ▼a School code: 0181.
650 4 ▼a Optics.
650 4 ▼a Medicine.
650 4 ▼a Biophysics.
690 ▼a 0752
690 ▼a 0564
690 ▼a 0786
71020 ▼a Princeton University. ▼b Electrical Engineering.
7730 ▼t Dissertations Abstracts International ▼g 81-04B.
773 ▼t Dissertation Abstract International
790 ▼a 0181
791 ▼a Ph.D.
792 ▼a 2019
793 ▼a English
85640 ▼u http://www.riss.kr/pdu/ddodLink.do?id=T15491425 ▼n KERIS ▼z 이 자료의 원문은 한국교육학술정보원에서 제공합니다.
980 ▼a 202002 ▼f 2020
990 ▼a ***1816162
991 ▼a E-BOOK