MARC보기
LDR00000nam u2200205 4500
001000000435100
00520200227114753
008200131s2019 ||||||||||||||||| ||eng d
020 ▼a 9781687972125
035 ▼a (MiAaPQ)AAI27602784
035 ▼a (MiAaPQ)OhioLINKosu1550776934984565
040 ▼a MiAaPQ ▼c MiAaPQ ▼d 247004
0820 ▼a 574
1001 ▼a Damon, Deidre Erin.
24510 ▼a Development of Functionalized Paper-Based Sample Collection and Direct Mass Spectrometry Analysis Platforms.
260 ▼a [S.l.]: ▼b The Ohio State University., ▼c 2019.
260 1 ▼a Ann Arbor: ▼b ProQuest Dissertations & Theses, ▼c 2019.
300 ▼a 188 p.
500 ▼a Source: Dissertations Abstracts International, Volume: 81-06, Section: B.
500 ▼a Advisor: Badu-Tawiah, Abraham.
5021 ▼a Thesis (Ph.D.)--The Ohio State University, 2019.
506 ▼a This item must not be sold to any third party vendors.
520 ▼a The goal of this dissertation is to develop a paper-based mass spectrometry (MS) ionization method for detection of small molecules from biological fluids and water samples. In biofluids, highly sensitive analytical methods are required to monitor small biologically active molecules during treatment. When analyzing both biofluids and industrial water samples, rapid and inexpensive detection platforms streamline screening for harmful concentrations of chemicals. Paper spray ionization shortens analysis time to less than one minute.Current analytical detection methods for these molecules include gas chromatography (GC)-MS, which is useful for creating databases for small molecules. However, GC-MS often requires extensive sample preparation and analyte derivatization prior to analysis. Liquid chromatography (LC)-MS offers better sensitivity without the need for derivatization. However, LC-MS is also limited by additional sample preparation/handling procedures. In particular, matrix components must be removed prior to any chromatographic work, which can be time consuming. For these reasons, immunoassay screening is still the most commonly used detection method for these small molecules despite their well-recognized limitations with regards to sensitivity and selectivity. Alternatively, paper spray (PS) ionization MS is capable of direct analysis of small biological sample volumes. However, PS often suffers from low sensitivity due to inefficient extraction.The second chapter in this document utilizes treated hydrophobic paper substrates prepared by a gas-phase silanization reaction. Hydrophobic PS utilizes online liquid/liquid extraction from a drop of biological fluid without drying steps or sample pretreatment, which is applicable in point-of-care analyses. Preliminary experiments demonstrated high sensitivity in the analysis of drugs cocaine, benzoylecgonine, methamphetamine, and amphetamine in 4 關L of raw blood, serum, and urine. When the sample is dried, a 3-dimensional dried spheroid is formed, as opposed to a dried blood spot. This spheroid decreases interaction between the bulk of the blood sample and ambient air, decreasing oxidative stress, increasing the lifetime of the analyte in the sample. Experiments show that labile organic compounds diazepam and cocaine have increased stability up to 28 days, where sample signal decreases by 90% within a day when stored in dried blood spots.The third chapter discusses the use of wax printing on paper. Wax printing creates microfluidic channels in which the designer can control solvent flow. Through this solvent control, spray time was increased from 1.5 minutes to 10 minutes. Additionally, because the solvent acts as the charge carrier, manipulation of the electric field decreased the required voltage applied to the paper triangle from 3-5 kV to 0.5-1 kV.The fourth chapter outlines the detection of low concentration corrosion inhibitor Duomeen O and molluscicide metaldehyde in industrial and environmental water samples. On-site analysis of Duomeen O would facilitate the maintaining of appropriate levels to prevent corrosion in water tube boiler plants. Because metaldehyde is readily soluble in water, runoff during periods of heavy rainfall ultimately introduces metaldehyde into drinking water. Paper spray ionization has been demonstrated as a viable technique for rapid screening and quantification of these molecules without sample preconcentration with detection limits below the threshold set by the World Health Organization.
590 ▼a School code: 0168.
650 4 ▼a Chemistry.
650 4 ▼a Health sciences.
650 4 ▼a Biochemistry.
690 ▼a 0485
690 ▼a 0566
690 ▼a 0487
71020 ▼a The Ohio State University. ▼b Chemistry.
7730 ▼t Dissertations Abstracts International ▼g 81-06B.
773 ▼t Dissertation Abstract International
790 ▼a 0168
791 ▼a Ph.D.
792 ▼a 2019
793 ▼a English
85640 ▼u http://www.riss.kr/pdu/ddodLink.do?id=T15494543 ▼n KERIS ▼z 이 자료의 원문은 한국교육학술정보원에서 제공합니다.
980 ▼a 202002 ▼f 2020
990 ▼a ***1008102
991 ▼a E-BOOK